12 SCREEN DISPLAYED ANOMALIES (USER)
After having turned the machine off and on again, if the problem persists communicate the type of error displayed
on the screen to technical assistance:
E1
Boiler sensor malfunction
E2
Tank sensor malfunction
E3
Water loading timeout ( the water loading duration has exceeded the time set in P9 )
E6
Draining anomaly. At the end of the draining phase the CPU still detects water in the Tank. This may be
due to: Drain pump malfunction, Drain tube blockage, Tank Pressostat malfunction, Drain cycle time set
too low
E7
30 minute Tank timeout
E8
15 minute boiler timeout