Instructions for the installer
5.3 Regulation for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been
adjusted for LPG, perform the same operations described in paragraph
“
6.2 Regulation for LPG”, but refer to the following table for the proper
injectors.
NG – 1.0 kPa
Burner
Nominal gas
consumption
(MJ/h)
Injector
(mm)
Auxiliary (1) 4.8 0.98
Semi rapid (2) 6.0 1.10
Rapid (3) 11.5 1.50
Rapid (4) 12.2 1.55
Wok (5) 15.0 1.70
15