Instructions for the User
51
ON -
ON 300 °C
OFF 500 °C
OFF 300 °C
13.6.3 Setting the cleaning cycle with electronic programmer
FUNCTION SELECTOR KNOB
CLEANING CYCLE MINIMUM DURATION: 1 h and 30’
Turn the function selector knob to the symbol, press the key and then press once to set the
minimum duration of : the thermostat light will come on. To display or adjust this duration, press
the key and the increase/decrease keys or . The duration of the pyrolysis cycle can be set up to
a maximum of 3 hours.
The cleaning cycle can be programmed to start at a preset time. Press the key and adjust the values
using the value variation keys or .
13.6.4 Setting the cleaning cycle with programmer+clock
FUNCTION SELECTOR KNOB
CLEANING CYCLE MINIMUM DURATION: 1 h and 30’
Turn the function selector knob to the symbol: the thermostat light will come on. Turn the knob A
anticlockwise to set the Pyrolysis duration in the window B.
The setting may be from a minimum of 1h 30' up to a maximum of 3 hours.