Smeg SSA91MFP1 Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
Instructions for the installer
3.2 Burner and nozzle characteristics table (Mod. 90 cm.)
Burner
Rated
heating
capacity
(kW)
LPG G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.0 50 30 350 73 71
Semi rapid 1.75 65 33 450 127 125
Rapid 3.0 85 45 800 218 214
Triple crown 3.2 91 65 1500 233 229
Oven 3.2 87 48 850 233 229
Maxi oven 5.2 110 59 1200 378 371
Grill 4.0 100 // // 291 286
Burner
Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.0 72 350
Semi rapid 1.75 97 450
Rapid 3.0 115 800
Triple crown 3.5 140 1500
Oven 3.2 130 850
Maxi oven 5.2 164 1200
3.3 Arrangement of the burners on the hob (Mod. 90 cm.)
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Triple crown
1
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 23 24

Comentarios a estos manuales

Sin comentarios