Contents 1. INSTRUCTIONS FOR SAFE AND PROPER USE_______________ 22 2. POSITIONING OF HOB ___________________________________ 24 3. ELECTRICAL CON
Instructions for the installer 30 5.2 Regulation for LPG Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C
Instructions for the installer 31 5.3 Regulation for G25/25 mbar The hob has been inspected for G25 (2L 3B/P) at a pressure of 25 mbar. To allow t
Instructions for the installer 32 6. FINAL OPERATIONS Having carried out the above adjustments, reassemble the appliance following, backwards, the
Instructions for the installer 33 6.3 Arrangement of burners on hob BURNERS 1 Auxiliary 2 Semi-rapid 3 Rapid 4 Ultra rapid 5 Double cro
Instructions for the user 34 7. USING THE HOB Before turning on the burners, make sure that the burner rings, caps and grids have been fitted
Instructions for the user 35 7.2 Practical advice for using the burners For better burner performance and minimum gas consumption, flat bottomed,
Instructions for the user 36 Raised indicators make for easier and clearer reading and use of the controls, each knob being connected to its corre
Instructions for the user 37 8. CLEANING AND MAINTENANCE Never use a steam jet to clean the appliance. Before any intervention, disconnect th
Instructions for the user 38 8.2 Cleaning of cooking hob components Grids, caps, flame cap crowns and burners can be removed for ease of cleaning.
Introduction 1. INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY
Introduction THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL NUMBER AND MARKING IS CLEARLY VISIBLE UNDER THE CASING. THE PLATE ON THE CAS
Instructions for the installer 24 2. POSITIONING OF HOB The following operation requires building and/or carpentry work so must be carried ou
Instructions for the installer 25 In case of installation on a hollow compartment with doors, a separating panel has to be placed under the hob
Instructions for the installer 26 3. ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power line conform to the data shown o
Instructions for the installer 27 4. GAS CONNECTION Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and
Instructions for the installer 28 4.1 Connection to LPG Use a pressure regulator and make the connection to the tank according to the provisions o
Instructions for the installer 29 5. ADAPTATION TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, detach the ap